To Turn OFF

Step 1: Turn the water off at the supply to the G4 Command Centre.

Step 2: Depress each lever on the HydroTap three or four times until the water stops. This will empty the tanks.

Step 3 [Commercial model]: Turn off power supply at the power point.

Step 3 [Residential model]: Turn off power supply using the power switch on the back right hand side of the Command Centre or the power point .


To Turn ON – HydroTap Boiling|Chilled

Have a bucket or container handy plus a towel to mop up any spills.

Step 1: Turn on water supply at supply point. Turn on power supply at power point. Note: any programmed times will be retained via the battery backup and will not need to be re-set.

Step 2: On the LCD screen, select [MENU] then [Install] and then [Filter Flush]. 

 
Step 3: Open the filter flush stop valve and ensure the end of the hose is in a bucket or sink. 



Step 4: Then select [Filter Flush START]. This will start the flow of water. Flush for 30 seconds to remove any water sitting in the filter cartridge.



Step 5: When the Filter Flush is finished, turn the stop valve to OFF by rotating the lever anti-clockwise until it is 90° to the hose. Replace the hose into the filter compartment.



Step 6: Press [Filter Flush - STOP] to end the filter flush process. Use the [Home] key to exit the Flush Menu. Wait for lights on tap to stop flashing and the unit will be ready for use.




To Turn ON – HydroTap Boiling|Chilled|Sparkling

Have a bucket or container handy plus a towel to mop up any spills.

Step 1: Turn on water supply at supply point. Turn on power supply at power point. Note: any programmed times will be retained via the battery backup and will not need to be re-set.

Step 2: On the LCD screen, press [MENU] then [Install] then [Filter Flush]. 

Step 3: Open the filter flush stop-valve and ensure the end of the hose is in a bucket or sink.



Step 4: Then select [Filter Flush START]. This will start the flow of water though the flush hose. Flush for 30 seconds to remove any water sitting in the filter cartridge.



Step 5: When the Filter Flush is finished, turn the stop-value to OFF by rotating the lever anti-clockwise until it is 90° to the hose. Return the hose into the filter compartment.



Step 6: Press [Filter Flush STOP] to end the filter flush process. Use the arrow key to exit the Flush Menu.

Step 7: Select [Co2 Purge].

Step 8: Select [Co2 Purge ON]. This will push Co2 and water through the HydroTap’s system.



Step 9: Let the Co2 flow until the water has finished and only Co2 is being dispensed from the tap. Leave the Co2 flowing for 5-10 seconds longer then press [Co2 Purge OFF] on the LCD screen.



Step 10: Exit by selecting the home screen.